• IEC 61010-2-101 Ed. 2.0 b:2015

IEC 61010-2-101 Ed. 2.0 b:2015

Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment

International Electrotechnical Commission, 01/23/2015

Publisher: IEC

File Format: PDF

$58.00$117.00


Published:23/01/2015

Pages:37

File Size:1 file , 450 KB

Note:This product is unavailable in Ukraine, Russia, Belarus

NEW! IEC 61010-2-101:2015 is available as IEC Standards+ 61010-2-101:2015 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 61010-2-101:2015 applies to equipment intended for in vitro diagnostic (IVD) medical purposes, including self-test IVD medical purposes. It has the status of a group safety function, as specified in IEC Guide 104. This standard has been prepared in close collaboration with Working Group CENELEC BTTF 88.1. This second edition cancels and replaces the first edition published in 2002. It constitutes a technical revision and includes the following significant changes from the first edition, as well as numerous other changes:
- excluded IEC 61010-2-081 (general laboratory equipment) from the scope. This separates IEC 61010-2-081 and IEC 61010-2-101 equipment;
- updated Biohazard and Lot symbols in Table 1 in Clause 5;
- added requirement for within expiration consumables and authorized representative details in Instructions for Use to Clause 5;
- added requirement for gas or liquid markings and ratings to Clause 5;
- added requirement to include OPERATOR instructions to deal with consumable or sample spills, jams or breakage inside equipment, disposal of hazardous waste, personal protection, RISK reduction procedures relating to flammable liquids, burns from surfaces, and loading and unloading of sample and reagents in Instructions for Use to Clause 5;
- added requirement for manufacturer to provide instructions on equipment transport, storage and removal from use to Clause 5;
- added normative reference ISO 18113-5 for instructions for use of self-test IVD medical equipment in Clause 5;
- added requirement for OPERATOR maintenance instructions to Clause 7;
- added requirements for sample zones and loading zones to Clause 7;
- excluded equipment whose size and weight make unintentional movement unlikely from drop test in Clause 8;
- added requirement for biohazard marking to Clause 13;
- added requirement for interlock systems containing electric/electronic or programmable components to Clause 15;
- added informative reference to Usability standard IEC 62366 to Clause 16;
- replaced Clause 17 with requirements of ISO 14971 for RISK assessment.
- Annex BB Instructions for use for self-testing IVD Medical Equipment deleted and a reference given to ISO 18113-5 in Clause 5.

This publication is to be read in conjunction with IEC 61010-1:2010.

Redline Note Redline notation is only applied to the English language version of the document.

More IEC standard pdf

IEC 60960 Ed. 1.0 b:1988

IEC 60960 Ed. 1.0 b:1988

Functional design criteria for a safety parameter display system for nuclear power stations

$25.00 $51.00

IEC 60404-10 Ed. 1.0 b:1988

IEC 60404-10 Ed. 1.0 b:1988

Magnetic materials. Part 10: Methods of measurement of magnetic properties of magnetic sheet and strip at medium frequencies

$60.00 $121.00

IEC 60951-1 Ed. 1.0 b:1988

IEC 60951-1 Ed. 1.0 b:1988

Radiation monitoring equipment for accident and post-accident conditions in nuclear power plants. Part 1: General requirements

$71.00 $143.00

IEC 60951-2 Ed. 1.0 b:1988

IEC 60951-2 Ed. 1.0 b:1988

Radiation monitoring equipment for accident and post-accident conditions in nuclear power plants. Part 2: Equipment for continuously monitoring radioactive noble gases in gaseous effluents

$48.00 $97.00