IEC 61223-3-2 Ed. 2.0 b:2007

Evaluation and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment

International Electrotechnical Commission, 07/10/2007

Publisher: IEC

File Format: PDF

$208.00$417.00


Published:10/07/2007

Pages:125

File Size:1 file , 900 KB

Note:This product is unavailable in Ukraine, Russia, Belarus

This part of IEC 61223 applies to the effectiveness of mammographic X-ray equipment, with respect to image quality and dose, in combination with aspects of equipment safety. This standard applies to mammographic X-ray equipment and mammographic stereotactic devices. The tests described in this standard require the quality and performance of the X-ray image receptors to be assured prior to the acceptance testing when they are not an integral part of the mammographic X-ray equipment. This includes radiographic films, intensifying screens, radiographic cassettes, storage phosphor plates and associated equipment such as film processors or storage phosphor plate readers, image display devices and hard copy cameras. For testing radiographic cassettes and intensifying screens, this standard makes reference to ISO 4090. Sensitivity and contrast for the screen-film image receptors are considered to be stated according to ISO 9236-3. By the measurements described in this standard, data for average glandular dose calculation can be determined. When the results of the acceptance test are in compliance with the expected values, the baseline values for the subsequent constancy tests are established. This part of IEC 61223 defines a) the essential parameters which describe the performance of the above-mentioned mammographic X ray equipment with regard to image quality and dose; and b) the methods of testing whether measured quantities related to those parameters comply with specified tolerances. These methods mainly rely on non-invasive measurements that use appropriate test equipment and are performed during or after the installation. Signed statements covering steps in the installation procedure can be used as part of the acceptance test. Tests required by a higher level of compliance take precedence over similar tests with a lower level of compliance.

More IEC standard pdf

IEC 60503 Ed. 2.0 b:1998

IEC 60503 Ed. 2.0 b:1998

Spools for broadcast videotape recorders (VTRS)

$25.00 $51.00

IEC 61986 Ed. 1.0 b:2002

IEC 61986 Ed. 1.0 b:2002

Rotating electrical machines - Equivalent loading and super-position techniques - Indirect testing to determine temperature rise

$54.00 $109.00

IEC 61010-2-101 Ed. 1.0 b:2002

IEC 61010-2-101 Ed. 1.0 b:2002

Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment

$78.00 $157.00

IEC 60050-551-20 Ed. 1.0 b:2001

IEC 60050-551-20 Ed. 1.0 b:2001

International Electrotechnical Vocabulary (IEV) - Part 551-20: Power electronics - Harmonic analysis

$47.00 $95.00