• NACE SP0508-2008

NACE SP0508-2008

Methods of Validating Equivalence to ISO 8502-9 on Measurement of the Levels of Soluble Salts

National Association of Corrosion Engineers, 11/07/2008

Publisher: NACE

File Format: PDF

$89.00$179.00


Published:07/11/2008

Pages:11

File Size:1 file , 180 KB

Note:This product is unavailable in Ukraine, Russia, Belarus

1.1.1 The assessment and determination of surface contamination (by salts) prior to application of protective coatings is critical to their service life expectancy. Determination of the level of surface cleanliness is conducted by extraction of soluble salt contaminants following ISO 8502-62--The Bresle method, part of ISO 8502-9. The determination of the level of salt is performed by following ISO 8502-9-- Field method for the conductometric determination of water-soluble salts. The field execution of this requirement involves using a syringe to inject deionized water into the Bresle patch, washing the substrate surface inside the patch, then extracting the test water for direct measurement of conductivity. Details of this procedure are provided in Appendix A (mandatory). Once a conductive value is determined by the conductivity meter, expressed as micro Siemens per centimeter. ISO 8502-9 provides a procedure to calculate the equivalent weight of the surface concentration as total surface density of the salts.

1.1.2 Step-by-step execution of the ISO 8502-6 and 8502-9 test requirements introduces a number of potential variances during the field evaluation. Some examples include the sensitivity and resolution of the conductivity meter, cycle time of the test water inside the Bresle patch, human errors in measuring and injecting the test water, and general operator experience. It is known that the accumulation of these individual process variances can add up to create an overall variance in the ISO protocol.

1.1.3 The range of variance in ISO 8502-6 and 8502-9 has been demonstrated by extensive laboratory tests conducted by a member of this task group.3 The precision of a single ISO 8502-9 test result was determined to be ±8.2 mg/m2 in the range 30 to 80 mg/m2. The absolute variance, and not the relative or percent variance, was found to be constant in this range. See Appendix B (nonmandatory) for details about these tests and the data analysis. The test method defined in ISO 8502-9 allows certain execution parameters of the test (e.g., size of adhesive patch, volume of test solution, and time of dissolution of salts inside the adhesive patch: the dwell time) to vary. This standard adopted best practices and has set the parameters in Appendix A. With a dwell time at a minimum of 90 seconds, the variance from operator error was found reduced dramatically in case the operator timing is not perfect. Hence, a dwell time of 90 seconds was adopted in Appendix A. For the purpose of defining equivalence, the procedure in Appendix A shall be used to create the reference values to which the candidate method will be validated. See Appendix B for the test rationale.

1.1.4 Any equivalent tools, methods, or procedures then must show that they meet the same criteria, thereby providing the same weight measures, and be within the same range of variance as would be produced by following the procedure in ISO 8502-9.

1.1.5 The objective of this standard is to determine whether methods other than the Bresle patch application method are suitable alternatives for measuring salt contamination in the field. Although tests may be performed on flat, horizontal surfaces for ease of use, each method should also be capable of gathering measurements on vertical and overhead surfaces. When such measurements cannot be made on vertical or overhead surfaces, this limitation must be noted in the validation report (Section 3).

More NACE standard pdf

NACE 1E100

NACE 1E100

Engineering Symbols Related to Cathodic Protection

$89.00 $179.00

NACE TM0193-2000

NACE TM0193-2000

Standard Test Method - Laboratory Corrosion Testing of Metals in Static Chemical Cleaning Solutions at TemperaturesBelow 93 Degrees C (200 Degrees F)

$89.00 $179.00

NACE 6A100

NACE 6A100

Coatings Used in Conjunction with Cathodic Protection

$89.00 $179.00

NACE 7H100

NACE 7H100

Evaluation of Boiler Tube Deposit Mass Loading (Deposit Weight Density) Methodology

$89.00 $179.00