• UL 1066

UL 1066

Low-Voltage AC and DC Power Circuit Beakers Used in Enclosures

Underwriters Laboratories, 04/13/2012

Publisher: UL

File Format: PDF

$114.00$229.66


Published:13/04/2012

Pages:29

Please note: All interim revisions for this edition available at time of your purchase will be included.

Low-Voltage AC and DC Power Circuit Breakers Used in Enclosures

UL 1066

1 Scope

1.1 These requirements cover low-voltage ac power circuit breakers as follows:

a) Stationary-mounted or drawout-mounted types,

b) 2-pole and 3-pole constructions,

c) Manually operated or power operated, and

d) With or without electromechanical or solid-state type trip device.

Section 1 effective April 13, 2012

1.2 These requirements apply to drawout-mounted type low-voltage ac integrally fused power circuit breakers, consisting of low-voltage ac power circuit breakers with integral current limiters or fuses.

1.3 These requirements apply to low-voltage ac fuse draw-outs consisting of current limiters or fuses in a drawout assembly intended to be connected in series with a low-voltage ac power circuit breaker to form a fused circuit breaker.

1.4 These requirements apply to general purpose type low-voltage dc power circuit breakers.

1.5 These requirements cover equipment intended for use in ordinary locations in accordance with the National Electrical Code, ANSI/NFPA 70.

1.6 These requirements are intended to supplement and be used in conjunction with the:

a) Standard for Low-Voltage AC Power Circuit Breakers Used In Enclosures, IEEE C37.13,

b) Standard for Low-Voltage DC Power Circuit Breakers Used In Enclosures, IEEE C37.14,

c) Standard for Metal-Enclosed Low-Voltage Power Circuit-Breaker Switchgear, IEEE C37.20.1,

d) Test Procedures for Switchgear - Low-Voltage AC Power Circuit Breakers Used In Enclosures, ANSI C37.50, and

e) Conformance Test Procedures for Switchgear - Metal-Enclosed Low-Voltage AC Power Circuit Breaker Switchgear Assemblies, ANSI C37.51.

1.7 These requirements cover equipment rated 600 V or less nominal, 635 V maximum ac and 300 V maximum dc.

1.8 This Standard does not apply to molded-case circuit breakers.

1.9 These circuit breakers are intended for installation in circuit breaker enclosures, switchboards (switchgear), panelboards, and the like. Drawout-mounted devices are intended for use with specific adapters or receiving equipment. The acceptability of the combination of a circuit breaker with respect to any overall enclosure will be determined when the complete product is considered.

More UL standard pdf

UL Subject 183

UL Subject 183

Standard for Manufactured Wiring Systems (Bulletin, 8/4/1998)

$101.00 $202.60

UL Subject 1020

UL Subject 1020

Standard for Thermal Cutoffs for Use in Electrical Appliances and Components (Bulletin, 9/26/2003)

$121.00 $243.38

UL Subject 2375

UL Subject 2375

HIP AND RIDGE SHINGLES (Outline, 12/15/2006)

$140.00 $280.73

UL Subject 2085

UL Subject 2085

Standard for Protected Aboveground Tanks for Flammable and Combustible Liquids (Bulletin, 9/26/2003)

$105.00 $210.68