• UL 1651

UL 1651

Optical Fiber Cable

Underwriters Laboratories, 07/08/2008

Publisher: UL

File Format: PDF

$102.00$204.54


Published:08/07/2008

Pages:18


1.1 These requirements cover single and multiple optical-fiber cables for control, signaling, and communications as described in Article 770 and other applicable parts of the National Electrical Code (NEC). Cables complying with these requirements are:Type OFNP - Plenum - A nonconductive cable for use in ducts, plenums, and other spaces used for environmental air. A nonconductive cable contains no metallic members and no other electrically conductive materials.Type OFCP - Plenum - A conductive cable for use in ducts, plenums, and other spaces used for environm0ental air. A conductive cable contains non-current-carrying conductive members such as metal strength members and metallic vapor barriers.Type OFNR - Riser - A nonconductive cable for vertical use in shafts or from floor to floor.Type OFCR - Riser - A conductive cable for vertical use in shafts or from floor to floor.Type OFN and OFNG - General Purpose - Nonconductive cables for general purpose use.Type OFC and OFCG - General Purpose - Conductive cables for general purpose use.

1.2 Smoke and fire considerations are as follows for the cables covered in these requirements:
1.TYPE OFNP and OFCP CABLES - Cables that are intended for installation in accordance with Section 770-53(a) of the National Electrical Code (ANSI/NFPA 70-1999) in a duct, plenum, or other space used to transport environmental air without the cable being enclosed in a raceway in that space are tested for smoke and flame characteristics in accordance with the Standard Test for Flame-Propagation and Smoke-Density Values for Electrical and Optical-Fiber Cables Used in Spaces Transporting Environmental Air (UL 910). A cable that complies exhibits a maximum flame-propagation distance that is not greater than 5 ft, 0 inch or 152 cm, a peak optical density of smoke produced of 0.50 or less (32 percent light transmission), and an average optical density of smoke produced of 0.15 or less.

More UL standard pdf

UL Subject 300

UL Subject 300

Standard for Fire Testing of Fire Extinguishing Systems for Protection of Commercial Cooking Equipment (CSDS Proposal, 11/16/2012)

$108.00 $217.62

UL Subject 2523

UL Subject 2523

Standard for Solid Fuel-Fired Hydronic Heating Appliances, Water Heaters, And Boilers (CSDS Proposal, 11/16/2012)

$141.00 $282.43

UL Subject 733

UL Subject 733

Standard for Oil-Fired Air Heaters and Direct-Fired Heaters (Bulletin, 8/30/2011)

$149.00 $298.07

UL 60730-2-3

UL 60730-2-3

Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Thermal Protectors for Ballasts for Tubular Fluorescent Lamps

$148.00 $297.30