• UL 1778

UL 1778

Uninterruptible Power Systems

Underwriters Laboratories, 09/15/2005

Publisher: UL

File Format: PDF

$117.00$235.31


Published:15/09/2005

Pages:72

Uninterruptible Power Systems

UL 1778

1.1 Scope

Replace this clause of the RD with the following:

1.1.1 Equipment covered by this standard

This Standard applies to UNINTERRUPTIBLE POWER SYSTEMS (UPS). The primary function of the UPS for this Standard is to ensure continuity of an alternating power source. The UNINTERRUPTIBLE POWER SYSTEM may also serve to improve the quality of the power source by keeping it within specified characteristics. This Standard is applicable to movable, stationary, fixed, and built-in UPS for distribution systems up to 600 V a.c. This equipment is designed to be installed in accordance with the Canadian Electrical Code, Part I, CSA C22.1, or the National Electrical Code, ANSI/NFPA 70, and, unless otherwise identified, the Standard for the Protection of Electronic Computer Data-Processing Equipment, ANSI/NFPA 75.

This Standard specifies requirements intended to ensure safety for the OPERATOR and, where specifically stated, for SERVICE PERSONNEL.

This Standard is intended to reduce the risk of fire, electric shock, or injury to persons from installed equipment, both as a single unit or as a system of interconnected units, subject to installing, operating, and maintaining the equipment in the manner prescribed by the manufacturer.

1.1.2 Additional requirements

In addition to the requirements in this Standard, a UPS is to comply with the UPS-relevant requirements of Information Technology Equipment Safety - Part 1: General Requirements, CAN/CSA-C22.2 No. 60950-1 / UL 60950-1, first edition, (RD), as applicable for the country where the product will be used. Wherever there is a conflict between the requirements of this document and the RD, the requirements of this Standard will prevail.

Engine-driven d.c. power generators intended to provide backup power for the battery supply circuit of UPS units are investigated for compliance with the requirements of the Standard for Stationary Engine-Generator Assemblies, UL 2200, and the CSA Standard for Motors and Generators, C22.2 No. 100.UPS that employ hospital grade components identified by the markings "Hospital Only", "Hospital Grade", or a green dot on the body of the component, or otherwise implying suitability for medical use are evaluated to the requirements of this Standard and Medical Electrical Equipment, Part 1: General Requirements for Safety, CAN/CSA-C22.2 No. 601.1 / UL 60601-1.

1.1.3 Exclusions

These requirements do not cover UPS units for use as emergency systems or as legally required standby systems, described in Articles 700 and 701, respectively, of the National Electrical Code, ANSI/NFPA 70, and Section 46 of the Canadian Electrical Code, Part I, CSA C22.1.Where considered appropriate, revision of requirements will be proposed and adopted in conformance with the methods employed for development, revision, and implementation of this Standard.NOTE 1: For equipment subject to transient overvoltages exceeding those for Category II according to IEC 60664, additional protection might be necessary. Such additional protection may be located in the mains supply to the equipment or in the equipment as an integral design feature.NOTE 2: Where the additional protection is an integral part of the equipment insulation requirements, CREEPAGE DISTANCES and CLEARANCE distances from the mains through to the load side of the additional protection may be judged as Category III or IV as required. All insulation requirements, CREEPAGE DISTANCES, and CLEARANCE distances on the load side of the additional protection may be judged as Category I or II as required.

This Standard does not cover all types of UPS, but it may be taken as a guide for such equipment. Requirements additional to those specified in this Standard are in some cases necessary for specific applications, e.g.:

a) equipment intended for operation while exposed, for example, to extremes of temperature; to excessive dust, moisture, or vibration; to flammable gases; to corrosive or explosive atmospheres; and

b) UPS equipment based on rotary machinery.

1.1.101 Normative References

Any undated reference to a code or a standard appearing in the requirements in this Standard is interpreted as referring to the latest edition of that code or standard. Annex ii lists CSA and UL standards used for the evaluation of components and features of products covered by this Standard or referenced in this document.

When compliance with multiple countries? codes or standards is required, but the product is not intended for use in all countries, the product need only comply with the codes or standards for the country or countries in which it is intended to be used.

For products intended for use in Canada, general requirements are given in CAN/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II.

More UL standard pdf

UL 263

UL 263

Fire Tests of Building Construction and Materials

$315.00 $631.00

UL Subject 199G

UL Subject 199G

Outline of Investigation for Fire Testing of Specific Application Sprinklers for Use in Attic Spaces (Outline, 8/9/2012)

$121.00 $243.92

UL 181B

UL 181B

Closure Systems for Use with Flexible Air Ducts and Air Connectors

$315.00 $631.00

UL Subject 2200

UL Subject 2200

Standard for Stationary Engine Generator Assemblies (CSDS Proposal, 8/6/2012)

$111.00 $223.62