• UL 2162

UL 2162

Standard for Commercial Wood-Fired Baking Ovens - Refractory Type

Underwriters Laboratories, 05/23/2014

Publisher: UL

File Format: PDF

$251.00$502.00


Published:23/05/2014

Note:This product is unavailable in Ukraine, Russia, Belarus

Please note: All interim revisions for this edition available at time of your purchase will be included.

Commercial Wood-Fired Baking Ovens - Refractory Type
UL 2162
1 Scope
1.1 These requirements apply to commercial wood-fired ovens intended for use by commercial establishments for the purpose of cooking or baking food products utilizing solid wood fuel. These ovens utilize as their primary enclosure, refractory materials.
1.2 For the purposes of this standard:
  • It is anticipated the ovens described in 1.1 will be vented by an exhaust hood as covered by the Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, NFPA 96, or an exhaust hood tested for compliance with the requirements in the Standard for Exhaust Hoods for Commercial Cooking Equipment, UL 710.
  • Minimum exhaust hood size including minimum height, depth, and length of the hood as well as minimum hood overhangs, minimum exhaust air flows, and maximum hood height above the oven shall be established as part of the investigation.
  • The seismic stability of the oven and support system is not anticipated in this document.
1.3 The wood-fired baking ovens as covered by these requirements are intended for installation in accordance with the National Electrical Code, NFPA 70, and other codes such as the International Mechanical Code and the Uniform Mechanical Code. The exhaust hoods referenced in these requirements are intended for installation in accordance with the Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, NFPA 96.

More UL standard pdf

UL Subject 823

UL Subject 823

Standard for Electric Heaters for Use in Hazardous (Classified) Locations (Bulletin, 7/21/1998)

$115.00 $231.12

UL Subject 181

UL Subject 181

Standard for Factory-Made Air Ducts and Air Connectors (Bulletin, 7/21/1998)

$113.00 $227.87

UL 1666

UL 1666

Test for Flame Propagation Height of Electrical and Optical-Fiber Cables Installed Vertically in Shafts

$115.00 $230.74

UL Subject 130

UL Subject 130

Standard for Electric Heating Pads (CSDS Proposal, 11/22/2005)

$126.00 $252.99