1 Scope

1.1 This Standard applies to equipment wiring terminals for use with all alloys of copper, aluminum, or copper-clad aluminum conductors, in accordance with the National Electrical Code, ANSI/NFPA 70, as follows:

a) equipment wiring terminals intended to hold one or more conductor(s);

b) equipment wiring terminals intended for use in appliances and equipment that comply with the requirements for such appliances and equipment;

c) ampere-rated equipment wiring terminals;

d) horsepower rated equipment wiring terminals; and

e) wire range rated equipment wiring terminals.

1.2 These requirements apply to field wired equipment wiring terminals which are an integral part of the equipment, or are intended for use in specific equipment.

1.3 This Standard is intended for equipment wiring terminals suitable for use with conductors in the size ranges as follows:

a) Aluminum

1) 12 AWG (3.3 mm2) and 10 AWG (5.3 mm2) solid; and

2) 12 AWG (3.3 mm2) to 2 000 kcmil (1 010 mm2) stranded, Class B concentric, compressed, and compact.

b) Copper-Clad Aluminum

1) 12 AWG (3.3 mm2) and 10 AWG (5.3 mm2) solid; and

2) 12 AWG (3.3 mm2) to 2 000 kcmil (1 010 mm2) stranded, Class B concentric.

c) Copper

1) 30 AWG (0.05 mm2) to 10 AWG (5.3 mm2) solid; and

2) 30 AWG (0.05 mm2) to 2 000 kcmil (1 010 mm2) stranded, Class B concentric and compressed, and Class C concentric.

d) Compact-stranded copper conductors for 2 AWG (33.6 mm2) and larger.

e) Rigid (solid and stranded) metric wire falling within the ranges of the above AWG sizes.

Note: For example, an equipment wiring terminal rated for 6 AWG - 250 kcmil may be additionally rated for 16 - 120 mm2.

f) Other class and strand configurations as indicated by marking.

1.4 This Standard is intended for equipment wiring terminals suitable for currents not exceeding the ampacity of insulated conductors rated 75?C or 90?C in accordance with the rating of the equipment wiring terminal, if provided.

1.5 This Standard does not apply to:

a) insulated equipment wiring terminals; and

b) wire binding screw terminals.

More UL standard pdf

UL Subject 60730-1

UL Subject 60730-1

Automatic Electrical Controls for Household and Similar Use; Part 1: General Requirements (CSDS Proposal, 3/23/2012)

$142.00 $284.68

UL Subject 1431

UL Subject 1431

Standard for Personal Hygiene and Health Care Appliances (CSDS Proposal, 11/30/2011)

$141.00 $282.22

UL Subject 263

UL Subject 263

Standard for Fire Tests of Building Construction and Materials (CSDS Proposal, 7/23/2010)

$122.00 $245.84

UL Subject 2127

UL Subject 2127

Standard for Inert Gas Clean Agent Extinguishing System Units (CSDS Proposal, 1/24/2014)

$124.00 $248.48