• UL 5085-3

UL 5085-3

Low Voltage Transformers - Part 3: Class 2 and Class 3 Transformers

Underwriters Laboratories, 04/17/2006

Publisher: UL

File Format: PDF

$499.00$998.00


Published:17/04/2006

Pages:40

Note:This product is unavailable in Ukraine, Russia, Belarus

Low Voltage Transformers - Part 3: Class 2 and Class 3 Transformers

5085-3

1 Scope

1.1 As noted in Low Voltage Transformers - Part 1: General Requirements, UL 5085-1, or CSA C22.2 No. 66.1, Low Voltage Transformers - Part 1: General Requirements, the requirements in Part 3 cover Class 2 transformers for use with Class 2 circuits in accordance with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, Part I, CSA C22.1. They are intended for connection to essentially sinusoidal supply sources.Advisory Note: For transformers intended for use in the United States, these requirements also cover Class 3 transformers for use with Class 3 circuits in accordance with the National Electrical Code, ANSI/NFPA 70, unless otherwise specified in this standard. See Annex d for Class 3 requirements.

1.3 In addition to the items specified in Clause 1.3 of Part 1, the requirements of Part 3 do not cover:

a) Power supplies (a transformer provided with a rectifier is considered a power supply);

b) Toy transformers;

c) Cord and plug connected transformers;

d) Direct plug-in transformers;

e) Transformers intended for use in audio, radio, or television type appliances; or

f) Other special types of transformers covered in requirements for other electrical devices or appliances.

Advisory Note: The requirements of Part 3 do not cover transformers intended for use in the United States having a nominal primary rating of more than 600 V and transformers having overvoltage taps rated over 660 V.

1.7 This part is intended to be used in conjunction with Part 1. The numbering of the clauses in Part 3 corresponds to the numbered clauses in Part 1. The requirements in Part 1 apply unless modified by Part 3.

1.8 A Class 2 transformer that includes a separate current-limiting impedance such as a resistor or a positive temperature coefficient device (PTC) is covered by these requirements.

1.9 A Class 2 transformer that includes a resonance regulating circuit is covered by these requirements.

More UL standard pdf

UL Subject 1652

UL Subject 1652

FLEXIBLE METALLIC TUBING (Bulletin, 7/7/2004)

$136.00 $272.35

UL Subject 48

UL Subject 48

Standard for Electric Signs (Bulletin, 7/2/2004)

$125.00 $250.61

UL Subject 2265

UL Subject 2265

Subject 2265 (Bulletin, 7/2/2004)

$146.00 $292.73

UL Subject 60601-1

UL Subject 60601-1

Medical Electrical Equipment, Part 1: General Requirements for Safety (Bulletin, 6/30/2004)

$118.00 $237.92