1 Scope

These requirements cover industrial control panels intended for general industrial use and installation in unclassified locations with intrinsically safe circuit extensions into the following hazardous (classified) locations in accordance with the National Electrical Code (NEC), NFPA 70:
  • a) Class I, Division 1;
  • b) Class I, Zone 0 and Zone 1;
  • c) Class II, Division 1;
  • d) Class III, Division 1; and
  • e) Zone 20 and Zone 21.
  • 1.2 The industrial control panels covered by these requirements are not intended for metal working machine tools, plastic injection molding, power press controls, flame safety supervision of combustible fuel type equipment, or elevator controls.

    1.3 These requirements do not cover electrostatic devices, circuits or systems, gas or vapor analysis equipment or other equipment having a process line brought into an enclosure.

    1.4 The industrial control panels covered by these requirements are assemblies consisting of components such as motor controllers, overload relays, fused disconnect switches, and/or circuit breakers and related control devices such as pushbutton stations, selector switches, pilot lights, timers, switches, control relays and the like with associated wiring terminals. In all cases, the enclosure is provided as part of the assembly.

    1.5 These requirements cover equipment for use under the following atmospheric conditions:
  • a) An ambient temperature not exceeding 40°C (104°F);
  • b) An oxygen concentration not greater than 21 percent by volume; and
  • c) A nominal barometric pressure of one atmosphere.
  • More UL standard pdf

    UL Subject 1424

    UL Subject 1424

    Standard for Cables for Power-Limited Fire-Alarm Circuits (Bulletin, 6/15/1998)

    $113.00 $227.49

    UL Subject 651

    UL Subject 651

    Standard for Schedule 40 and 80 Rigid PVC Conduit (Bulletin, 6/12/1998)

    $111.00 $222.84

    UL Subject 2092

    UL Subject 2092

    Subject for Pre-Engineered Wet-Chemical Extinguishing System Units (Bulletin, 6/10/1998)

    $111.00 $222.15

    UL Subject 2085

    UL Subject 2085

    Standard for Protected Aboveground Tanks for Flammable and Combustible Liquids (Bulletin, 6/10/1998)

    $118.00 $236.42